IMERG Early Run Example January 24th, 2020

Data News

Late on March 2, 2016, the GPM NRT system will begin using V04 algorithms for: Level 1B GMI Level 1C GMI Level 1 Radar Level 2 Radar Level 2 Combined V04 is the first version that uses GPM as the calibrator for the constellation rather than TRMM. The GPROF database is built using the combined observations. GMI is extremely well calibrated and the brightness temperatures in 1B and 1C are an important improvement over those in V03. V04 also made improved retrievals in the Ku, Ka, and DPR Level 2 products. Combined has also made retrieval improvements in this version. GPROF the algorithm used for...
PPS will commence Version 4 processing of GPM and Partner satellite products in early March 2016. All current Version 3 products will be processed through February 29, 2016. Once the current products are completed there will be a delay before the first version 4 products will be made available to the public. The first data date for version 4 will be March 1, 2016. Once PPS has verified the processing and products for version 4 they will be released and made available from our ftp site. At this time PPS will commence reprocessing. GPM products will be reprocessed back to launch, March 2014...
UPDATE 2/22/16: The network upgrades have finished and normal service has been restored. Due to scheduled external GSFC network upgrades, PPS will experience intermittent and unpredictable network outages during the period of Friday February 19, 2016 (starting 8:00PM EST-0100 UTC) through Monday February 22, 2016 (3:00 AM EST-0800 UTC). This work will impact access to the following PPS services: PPS ftp production data (arthurhou) PPS ftp NRT data-Near Realtime (jsimpson) PPS Public website: http://pps.gsfc.nasa.gov/ STORM: https://storm.pps.eosdis.nasa.gov/ PMM website: http://pmm.nasa.gov...
The Washington, DC area is about to get hit with a record-level snow storm, with attendant disruptions to work schedules, travel, communications, and power. If you find that the TMPA-RT products drop out, it is safe to assume that some combination of these effects is preventing production, and we will work to restore service when that is possible.
With the turnover of the year to 2016, the suite of 3B40RT, 3B41RT, and 3B42RT failed to process. Despite the holiday weekend, this was traced to a very old quality control on the date/time, fixed, and retrospectively processed to give a complete time series. Thanks to Erich Stocker and David Bolvin for this effort. The affected date/times are 160101 00UTC through 160102 12UTC.

Hide Date